MODULAR LOW VOLTAGE SWITCHGEAR SYSTEM WITH FIXED CUBICLE |
![]() |
![]() |
![]() |
![]() -Rated service voltage 690V 50-60Hz -Rated insulation voltage 1000V 50-60Hz -Rated short-time withstand current (r.m.s. value) for 1 second <=70kA -Rated short-time withstand current (peck value) 120kA -Power frequency test voltage for 1 min. 8kV -Rated current <=2000A Mechanical characteristics -External degree of protection IP30-IP54 -Inside degree of protection (handed open) IP2x -Forms of internal separations 3B -Painting Dusts -Color RAL7030-7032-7035 -Not painted surfaces Galvanize -Standard complied with CEI60439-IEC439-1 -Accessibility Anterior/back -Entered cables Top/low Size -Depth 400-500-600-800mm -height 2000-2200-2400mm -Width (1 column + vain connections) 900mm SWITCHBOARD COMPOSITION Modularity switchboard Available height = 1800mm 18 forms switchboard H2000mm Available height = 2000mm 20 forms switchboard H2200mm Available height = 2200mm 22 forms switchboard H2400mm Every form measure 100mm Every column can be divided on the base of the demands of the install and to be equipped with different typologies of equipments at the same time : -Circuit-breakers/on-load isolators max 2000A -Outgoing feeders max 1250A -Direct starters max 250kW -Inverter starters max 250kW -Soft-start starters max 250kW -Instruments -Modular circuit breakers max. 125A -PLC ![]() ENCUMBRANCES DIRECT STARTER (CIRCUIT- BREAKER + CONTACTOR)
![]() ENCUMBRANCES REVERSER STARTER (CIRCUIT-BREAKER+CONTACTOR)
![]() ENCUMBRANCES STAR/DELTA STARTER (CIRCUIT-BREAKER+CONTACTOR)
![]() ENCUMBRANCES INVERTER/SOFT START STARTER (FUSES OF PROTECTION+CONTACTOR)
![]() SWITCHBOARD COMPOSITION INSTRUMENTATION AND PLC PANEL The instruments and plc panel are accessible through openable panel provided of lock. The equipments can have fixed inside the cubicle or directly on the door or on special modular panels. The panels have the following modularity: 1Mod =100mm The possible measures go from 100mm to 2200mm. ![]() MCC WITH FRONTAL ACCESSIBILITY CHARACTERISTICS This type of closet is used in applications where the switchboard can be placed to the wall or behind another switchboard. This structure makes the copper bar system accessible after the istallation so that to allow the insertion of new uses and to facilitate the periodic maintenance. ![]() A - Vain gone up again additional for connection to the general interrupter. B - Vertical omnibus Bars on every column C - Protection in insulating material D - Useful Depth of wiring E - Terminal block of connection F - Superior vertical bars G - Stirrups for fixing cable MCC WITH BACK ACCESSIBILITY CHARACTERISTICS This type of closet is used in applications where the switchboard can be accessible from the front and from the back. In this structure the copper bar system is placed on the back side making the front side totally exploitable. In this case the cable vain are used only for the external connections to the switchboard allowing an optimization of the encumbrances. ![]() A - horizontal principal omnibus Bars B - vertical omnibus Bars on every column C - useful Depth of wiring D - Terminal block of connection C - Stirrups for fixing cable F - Segregation vain cables |
< Previous | Next > |
---|